easy-guard Class '0' Barrier compound.
easy-guard Class ‘0’ intumescent paint system successfully upgrades the Warringtonfire ‘Blue Board’ to Class 0 when tested to BS476 Parts 6 & 7.
Kenton School in Newcastle protects corridors and classrooms with easy-on protective coating.
- Product Overview
- Benefits
- Application Guide
- Data Sheets
- Brochure
- Price List
Overview - easy-guard Class '0' Barrier compound
The easy-guard class '0' intumescent paint system has been designed in partnership with Exova Warringtonfire.
This passive fire protection product is a must for all communal areas where multiple layers of paint have been allowed to build up. If a fire breaks out, these layers of paint can ignite and the flames can chase down a wall or across a ceiling using the paint as part of its fuel. Combustion of this sort is fast and ferocious and tests have shown fires can chase down corridors or up stairwells faster than most people can run. It is for this reason that the Department of Trade and Industry's (DTI's) Fire Safety Code of Practice recommends that where multiple layers of paint exist, walls should be stripped back to bare plaster (a very expensive operation) or encapsulated with a fire retardant paint.
easy-guard Class '0' barrier compound is an intumescent fire paint and in the worst case Warringtonfire "blue board" test gained a Class '0' rating for BS476 parts 6 & 7. easy-guard Class '0' fire retardant paints are available in any RAL or BS colour to compliment and enhance the living environment and have been tested to BS476 along with the easy-on anti vandal paint system.
By using easy-guard Class '0' fire paint and easy-on anti graffiti paint together you can guarantee clean, Class '0', fire retardant walls for up to 20 years without having to worry about your passive fire protection efforts being compromised by overzealous graffiti removal, a common problem in schools and tower blocks.
easy-guard Class ‘0’ intumescent fire paint enables architects, building owners and surveyors to comply with Section B2 of the Building Regulations act and also to fulfil their obligations under the Regulatory Reform (Fire Safety) Order (RRFSO).
Our experienced intumescent and fire paint specialists are on hand to help and advise you so please contact us today to arrange a FREE OF CHARGE paint adhesion assessment and begin your journey to safe Class '0' walls.
easy-guard features & benefits
|
Class '0' fire protection for:
|
Application Guide
easy-guard - fire upgrade coating - Class "0"
General Specification:
1. Attend site and carry out adhesion tests to
pre-painted wall and ceiling surfaces.
2. Identify any areas of weak inter-coat
adhesion and scrape back to a hard edge.
3. Feather off as necessary.
4. Thoroughly abrade all glossy/hard surfaces
down and degrease with easy-guard Wash
Down Agent and rinse with clean water.
5. To clean dry surfaces apply 1 coat of easyguard
Class “0” Bond Primer by brush/
roller at a coverage rate of 14-16m²/litre
Allow at least 1 hour drying time.
6. Apply 1 coat of easy-guard Class “0”
Barrier Compound by brush/roller at a
coverage rate of 0.45m2/litre. Pattern as
necessary and lace down when hard dry.
7. Apply 1 coat of easy-guard Class “0”
Colour Coat by brush/roller at a coverage
rate of 6-12 m²/litre. Allow at least 8
hours drying time.
8 Provide Contract Administrator with Fire
Test Certificates demonstrating Class “0”
performance over the Warrington “Blue”
Board in full accordance with the
Warrington Application Monitoring
Procedure.