4.5Ltr easy-on+ anti bacterial coating
easy-on+ anti bacterial coating is the hard wearing alternative to silver ion technology. Perfect for hospital walls and an essential tool in the fight against hospital acquired infections (HAI's).
easy-on goes global - Artists from around the world paint these globes to raise peoples awareness of Global Warming.
- Overview
- Benefits
- Application Guide
- Data Sheets
- Brochure
- Price List
- Videos
- NBS+
easy-on+ anti bacterial coating
easy-on+ anti bacterial coating incorporates Akacid (plus), a biocide proven to disrupt the cell surfaces of bacteria and reduce hospital acquired infections including MRSA, E Coli, Salmonella and Listeria.
Tests by the biomedical research department at Sheffield Hallam University have shown that when panels coated with easy-on+ were contaminated the added Akacid (plus) provided continuous protection from bacterial infection, HAI’s and fungal growth and eliminated all hospital pathogens within 340 minutes. This evidence combined with easy-on’s durable nature make easy-on+ anti bacterial coating a longer lasting and more cost effective alternative to silver ion technology.
easy-on+ anti bacterial coating is perfect for all situations where hygiene is essential, easy-on+ should be used to offer anti bacterial protection in hospitals, vets and food preparation areas. Once applied easy-on+ still offers all the benefits of our standard easy-on protective coating and will withstand 100's of cleaning cycles and last for up to 20 years. easy-on+ anti bacterial coating is available as a clear finish and can be applied over any existing bare or painted surface including brick, stone, plaster, metal, powder coatings, plastics and woods.
easy-on+ anti bacterial coating enables hospitals, vets and food preparation companies to save money whilst reducing infection and improving the aesthetic environment.
easy-on anti bacterial coating = visibly clean and hygienically clean walls and surfaces for up to 20 years.
Features & Benefits
|
easy-on is perfect for:
|
Application Guide
Coating performance is proportional to the degree of surface preparation. Surface must be clean, dry (<6% moisture), undamaged and free of all contaminants prior to coating.
Prepare damaged areas to original surface preparation specifications, feathering edges of any intact coating system.
For optimum application, temperature of the material should be between 10ºC and 20ºC prior to mix and application.
Gradually add total contents of Cure tin into Resin tin and stir thoroughly to a uniform consistency.
Apply by brush, small roller or spray*, without thinning.
Use a cross-lapping method of application ensuring corners and edges are covered and avoid misses. If the surface is highly porous do not attempt to cover with one application. Apply a thin coat, leave for 3 - 4 hours to partially reduce porosity, and then apply a second light and even coat.
Many modern surfaces, especially when new, have a layer of grease, oil or other contaminants on them. To ensure good adhesion it is important these surfaces are thoroughly cleaned with a water based degreaser and that the degreaser used is then washed away before attempting to apply the coating. Both the contaminants and the degreaser can reduce adhesion so cleanliness must be considered critical.
Stainless Steel: Abrade, sweep blast or high pressure water blast.
Aluminium: Degrease followed by abrading blast or chemical conversion treatment.
Galvanizing: Degrease followed by abrading or chemical conversion treatment.
Concrete: New concrete - Acid etch or abrade to remove laitence. Aged concrete must be thoroughly cleaned.
Aged Coatings: All surfaces must be clean & dry, tightly bonded and free of loose flakes and corrosion products.
Brick/stone: All surfaces must be clean and dry and free of loose material.
Timber etc: Ensure surfaces are clean and dry.
SPRAY INSTRUCTIONS:
HVLP+ Walter pilot:
- Use 2,2 bar pressure with the 1,8 mm nozzle.
- WFT should be between 25 and 40 microns.
- Use 0,2 bar material pressure and 3,5 bar assisted air pressure.
- Apply the recommended WFT of around 25/30 microns.
Conventional air spray (pressure pot):
ALWAYS CLEAN OUT THE UNIT THOROUGHLY WHEN FINISHED SPRAYING. LEAVE SMALL AMOUNT OF CLEANER IN THE SPRAY POT.
Video Demonstrationeasy-on hygiene finish not only resists germs and bacteria but graffiti and scuff marks too. We have prepared this video demonstration to evidence what incredible durability and scuff resistance the easy-on hygiene finish really has. We hope you enjoy it. The video lasts around 4 minutes. No cheating or camera trickery was used in the making of this film. |
NBS+
easy-on protective coating is listed on the NBS Building specification system.
NBS building is a library of pre-written specification clauses with extensive guidance, suitable for a wide variety of construction projects.
Simply click the link below then scroll to down to find "easy-on protective coating".
The easy-on clause is authored in NBS format and is intended for inclusion in project specifications. From here the clause can be copied and pasted into your project specification document.