easy-on versatile protective finish: 4.5ltr
easy-on is the one coat, transparent finish that resists graffiti, damage and attack for up to 20 years. Prevention is always better than cure.
Subart mural in Croydon brightens up another Subway and looks fantastic.
- Overview
- Benefits
- Application Guide
- Data Sheets
- Brochure
- Price List
- Videos
- NBS+
easy-on versatile protective finish
easy-on is the hard wearing protective finish for all situations. Originally designed to protect Oil rigs in the North Sea this fantastically tough, non-stick coating has subsequently found a million uses here on dry land.
easy-on was introduced to the UK by Urban Hygiene around 10 years ago and it quickly found a calling as the UK's number one, "true permanent" anti graffiti coating. A title it still holds today. easy-on was extensively tested by the National Materials Research Institute and shown to withstand 100's of cleaning operations and resist all forms of graffiti. Non-stick easy-on can be cleaned using mild and safe graffiti removers and will last up to 20 years without ever needing to be reapplied.
Following this success easy-on protective coating quickly became a favourite with Schools and Housing associations who use it as a durable finish for corridors and stairwells. One coat applied over newly painted walls enables cleaning to take place where redecoration had previously been the only option. This not only enables building and facility managers to keep on top of appearances but also saves building owners many thousands of pounds in annual redecoration costs by extending redecoration intervals up to 20 years if required.
Most recently easy-on has been tested by the Biomedical Research Team at Sheffield Hallam University and has been proven to resist the top 10 hospital acquired infections (HAI's). This latest incarnation will see will see easy-on being used as a Hygiene Finish in wards and theatres where its washable nature and long life will ensure cleaner hospitals for us all whilst saving the Health service millions of pounds in decoration costs.
easy-on protective finish can now be found all over the world in hundreds of different guises. easy-on protects surfaces permanently and is a fantastic low cost alternative to wall cladding systems.
See how easy-on can make your life easier by clicking "buy now" today.
easy-on benefits
|
easy-on is used by:
|
Application Guide
Coating performance is proportional to the degree of surface preparation. Surface must be clean, dry (<6% moisture), undamaged and free of all contaminants prior to coating.
Prepare damaged areas to original surface preparation specifications, feathering edges of any intact coating system.
For optimum application, temperature of the material should be between 10ºC and 20ºC prior to mix and application.
Gradually add total contents of Cure tin into Resin tin and stir thoroughly to a uniform consistency.
Apply by brush, small roller or spray*, without thinning.
Use a cross-lapping method of application ensuring corners and edges are covered and avoid misses. If the surface is highly porous do not attempt to cover with one application. Apply a thin coat, leave for 3 - 4 hours to partially reduce porosity, and then apply a second light and even coat.
Many modern surfaces, especially when new, have a layer of grease, oil or other contaminants on them. To ensure good adhesion it is important these surfaces are thoroughly cleaned with a water based degreaser and that the degreaser used is then washed away before attempting to apply the coating. Both the contaminants and the degreaser can reduce adhesion so cleanliness must be considered critical.
Stainless Steel: Abrade, sweep blast or high pressure water blast.
Aluminium: Degrease followed by abrading blast or chemical conversion treatment.
Galvanizing: Degrease followed by abrading or chemical conversion treatment.
Concrete: New concrete - Acid etch or abrade to remove laitence. Aged concrete must be thoroughly cleaned.
Aged Coatings: All surfaces must be clean & dry, tightly bonded and free of loose flakes and corrosion products.
Brick/stone: All surfaces must be clean and dry and free of loose material.
Timber etc: Ensure surfaces are clean and dry.
SPRAY INSTRUCTIONS:
HVLP+ Walter pilot:
- Use 2,2 bar pressure with the 1,8 mm nozzle.
- WFT should be between 25 and 40 microns.
Conventional air spray (pressure pot):
- Use 0,2 bar material pressure and 3,5 bar assisted air pressure.
- Apply the recommended WFT of around 25/30 microns.
ALWAYS CLEAN OUT THE UNIT THOROUGHLY WHEN FINISHED SPRAYING. LEAVE SMALL AMOUNT OF CLEANER IN THE SPRAY POT.
Video DemonstrationSeeing is believing so we have prepared an easy-on coating demonstration for your viewing pleasure. The video lasts around 4 minutes and contains no cheating or camera trickery. |
NBS+
easy-on protective coating is listed on the NBS Building specification system.
NBS building is a library of pre-written specification clauses with extensive guidance, suitable for a wide variety of construction projects.
Simply click the link below then scroll to down to find "easy-on protective coating".
The easy-on clause is authored in NBS format and is intended for inclusion in project specifications. From here the clause can be copied and pasted into your project specification document.